• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Previously Unrecognized Source of Error in the Change in Maximum Total Point Motion to Determine Continuous Migration of Unstable Tibial Baseplates

    Thumbnail
    View/Open
    bio_144_02_024504.pdf (245.6Kb)
    Date
    2021
    Author
    Niesen, Abigail E.
    Hull, Maury L.
    Metadata
    Show full item record
    Abstract
    In radiostereometric analysis (RSA), continuous migration denoted as ΔMTPM is the difference between maximum total point motion (MTPM) at 2 years relative to time zero and MTPM at 1 year relative to time zero. Continuous migration has been used to diagnose tibial baseplates as stable versus unstable when compared to a specified stability limit (i.e., value of ΔMTPM). If the same point experiences MTPM at 2 years and at 1 year (usually the case for marker-based RSA), then an implicit assumption is that the migration path between 2 years and 1 year is the same as the path between 1 year and time zero. This article uses vector analysis to demonstrate a source of error in ΔMTPM not previously recognized and estimates the magnitude of error based on the interplay of independent variables which affect the error. The two independent variables which affect the error are the angle between the two migration vectors (i.e., MTPM between time zero and 2 years and MTPM between time zero and 1 year) and the difference in magnitude of the two vectors. The relative error increased in an absolute sense as the angle between the vectors increased and decreased for larger differences in the magnitudes of the two vectors. For magnitude ratios ranging from 1.25 to 2, relative errors ranged from –21% to –3% at 10 deg and from –78% to –42% at 60 deg, respectively. Knowledge of these errors highlights a limitation in the use of ΔMTPM not previously recognized.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4284830
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV