dc.contributor.authorMohsenian, Ghazal
dc.contributor.authorHoang, Cong Hiep
dc.contributor.authorNemati, Kourosh
dc.contributor.authorAlissa, Hussam
dc.contributor.authorTradat, Mohammad
dc.contributor.authorFallahtafti, Najmeh
dc.contributor.authorRadmard, Vahideh
dc.contributor.authorMurray, Bruce
dc.contributor.authorSammakia, Bahgat
dc.date.accessioned2022-05-08T09:07:51Z
dc.date.available2022-05-08T09:07:51Z
dc.date.copyright2/23/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn1043-7398
dc.identifier.otherep_144_04_041015.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284760
dc.description.abstractThe practice of commissioning data centers (DCs) is necessary to confirm the compliance of the cooling system to the information technology equipment (ITE) load (design capacity). In a typical DC, there are different types of ITE, each having its physical characteristics. Considering these geometrical and internal differences among ITE, it is infeasible to use the actual ITE as a self-simulator. Hence, a separate device called load bank is employed for that purpose. Load banks create a dummy thermal load to analyze, test, and stress the cooling infrastructure. Available commercial load banks do not accurately replicate a server's airflow patterns and transient heat signatures which are governed by thermal inertia, energy dissipation, flow resistance, and fan system behavior. In this study, a novel prototype of the server called server simulator was designed and built with different components to be used as a server mockup. The server simulator accurately captured air resistance, heat dissipation, and the functionality of actual server behavior. Experimental data showed up to 93% improvement in ITE passive and active flow curves using the designed server simulator compared to the commercial load bank. Furthermore, the experimental results demonstrated a below 5% discrepancy on the critical back pressure and free delivery point between the actual ITE and the designed server simulator. In addition, experimental data indicated that the developed server simulator improved the actual ITE thermal mass by 27% compared to the commercial load bank.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Novel Design of Rack Mount Server Thermal Simulator: Design, Assembly, and Experimental Verification
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue4
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.4053643
dc.journal.fristpage41015-1
dc.journal.lastpage41015-9
dc.page9
dc.treeJournal of Electronic Packaging:;2022:;volume( 144 ):;issue: 004
dc.contenttypeFulltext