• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Turbomachinery
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Turbomachinery
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Sweep Effects on Fan–Intake Aerodynamics at High Angle of Attack

    Thumbnail
    View/Open
    turbo_144_10_101001.pdf (1.741Mb)
    Date
    2022
    Author
    Mohankumar, Ben
    Hall, Cesare A.
    Wilson, Mark J.
    Metadata
    Show full item record
    Abstract
    Sweep in a transonic fan is conventionally used to reduce design point losses by inclining the passage shock relative to the incoming flow. However, future low pressure ratio fans operate to lower Mach numbers meaning the role of sweep at cruise is diminished. Instead, sweep might be repurposed to improve the performance of critical high Mach number off-design conditions such as high angle of attack (AOA). In this article, we use unsteady computational fluid dynamics to compare two transonic low pressure ratio fans, one radially stacked and one highly swept, coupled to a short intake design, at the high AOA flight condition. The AOA considered is 35 deg, which is sufficient to separate the intake bottom lip. The midspan of the swept fan was shifted upstream to add positive sweep to the outer span. Based on previous design experience, it was hypothesized that the swept fan would reduce transonic losses when operating at high AOA. However, it was found that the swept fan increased the rotor loss by 24% relative to the radial fan. Loss was increased through two key mechanisms. (i) Rotor choking: flow is redistributed around the intake separation and enters the rotor midspan with high Mach numbers. Sweeping the fan upstream reduced the effective intake length, which increased the inlet relative Mach number and amplified choking losses. (ii): Rotor-separation interaction (RSI): the rotor tip experiences low mass flow inside the separation, which increases the pressure rise across the casing to a point where the casing boundary layer separates. The swept fan diffused the casing streamtube, causing the casing separation to increase in size and persist in the passage for longer. High RSI loss indicated that the swept fan was operating closer to the rotating stall point.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4284468
    Collections
    • Journal of Turbomachinery

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV