Show simple item record

dc.contributor.authorIffrig, Elizabeth
dc.contributor.authorTimmins, Lucas H.
dc.contributor.authorEl Sayed, Retta
dc.contributor.authorTaylor, W. Robert
dc.contributor.authorOshinski, John N.
dc.date.accessioned2022-05-08T08:42:24Z
dc.date.available2022-05-08T08:42:24Z
dc.date.copyright4/19/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_09_091011.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284237
dc.description.abstractWall shear stress (WSS) is an important mediator of cardiovascular pathologies and there is a need for its reliable evaluation as a potential prognostic indicator. The purpose of this work was to develop a method that quantifies WSS from two-dimensional (2D) phase contrast magnetic resonance (PCMR) imaging derived flow waveforms, apply this method to PCMR data acquired in the abdominal aorta of healthy volunteers, and to compare PCMR-derived WSS values to values predicted from a computational fluid dynamics (CFD) simulation. The method uses PCMR-derived flow versus time waveforms constrained by the Womersley solution for pulsatile flow in a cylindrical tube. The method was evaluated for sensitivity to input parameters, intrastudy repeatability and was compared with results from a patient-specific CFD simulation. 2D-PCMR data were acquired in the aortas of healthy men (n = 12) and women (n = 15) and time-averaged WSS (TAWSS) was compared. Agreement was observed when comparing TAWSS between CFD and the PCMR flow-based method with a correlation coefficient of 0.88 (CFD: 15.0 ± 1.9 versus MRI: 13.5 ± 2.4 dyn/cm2) though comparison of WSS values between the PCMR-based method and CFD predictions indicate that the PCMR method underestimated instantaneous WSS by 3.7 ± 7.6 dyn/cm2. We found no significant difference in TAWSS magnitude between the sexes
dc.description.abstract8.19 ± 2.25 versus 8.07 ± 1.71 dyn/cm2, p = 0.16 for men and women, respectively.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA New Method for Quantifying Abdominal Aortic Wall Shear Stress Using Phase Contrast Magnetic Resonance Imaging and the Womersley Solution
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue9
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4054236
dc.journal.fristpage91011-1
dc.journal.lastpage91011-11
dc.page11
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record