dc.contributor.authorDing, Zhikou
dc.contributor.authorLi, Wei
dc.contributor.authorWang, Lei
dc.contributor.authorZhao, Limin
dc.contributor.authorSherif, S. A.
dc.contributor.authorWang, Ru
dc.contributor.authorKabelac, Stephan
dc.date.accessioned2022-05-08T08:41:57Z
dc.date.available2022-05-08T08:41:57Z
dc.date.copyright11/23/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn0199-6231
dc.identifier.othersol_144_2_021005.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284228
dc.description.abstractFalling film evaporation is widely used in solar desalination systems. Fouling is an important problem to be addressed in many applications involving heat transfer including processes involving the utilization of solar energy in desalination applications. In the research upon which this paper partly reports, an experimental investigation was carried out on a vertical tube in falling film evaporation to determine the effects of temperature, velocity, the use of a porous-sintered tube, and the use of Teflon coating on calcium carbonate deposition characteristics. During the fouling experiments, the pressure inside the test tubes was maintained constant at 101.3 kPa, and the inlet temperature was maintained at 373 K, while allowing the water mass velocity to vary from 0.42 to 1.05 kg m−1 s−1. Results show that the fouling in the test tube becomes more serious as the temperature increases and the flowrate decreases. Compared with stainless-steel tubes, porous-sintered tubes can significantly reduce fouling resistance, but at the same time they bring about a decrease in the heat transfer coefficient. The Teflon coating also has anti-fouling performance but does not affect the heat transfer coefficient in stainless-steel tubes. Through the weighing of local fouling deposits, it has been found that the mass of the fouling deposits in the lower part of the tested tubes is greater than that in the upper part.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental Study on CaCO3 Fouling Characteristics During Falling Film Evaporation
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue2
dc.journal.titleJournal of Solar Energy Engineering
dc.identifier.doi10.1115/1.4052937
dc.journal.fristpage21005-1
dc.journal.lastpage21005-10
dc.page10
dc.treeJournal of Solar Energy Engineering:;2021:;volume( 144 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record