dc.description.abstractThe paper is devoted to elaboration of the analytical O-procedure for the limit load analysis of complex shaped axial defect in a pressurized pipe. It is based on the classical lower bound theorem of the theory of plasticity, and consists in construction of the statically admissible solution, where distribution of stress satisfies to the equilibrium equations and strength conditions. O-procedure is an optimization process to get the most favorable stress distribution for providing the maximal pressure. It allows to explicitly account for the variable geometrical and physical parameters. Contrary to other approaches, the derived formula for rectangular defect is only a particular case of the general procedure application. Four different methods for the complex defects are compared. They are: first, ASME, A-, rectangular defect formula combined with RSTRENG, R-, procedure, i.e., A–R approach
dc.description.abstractsecond, PCORRC, P-, formula with R-procedure, P–R approach
dc.description.abstractthird, Orynyak's, O-, formula with R-procedure, O–R approach
dc.description.abstractand fourth, our universal O-procedure. The verification begins for rectangular defects where both theoretical and experimental comparison is performed for A-, P-, and O- formulas. The difference between them is small, provided that all three employ the same characteristic of material, here the ultimate strength. Then theoretical comparison for A–R, P–R, O–R approaches and O-procedure is performed for the artificial complex defects, for two symmetrical rectangular defects, for triangular defect. Experimental comparison between four methods is made based on the well-known University of Waterloo full scale tests.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalytical Limit Load Procedure for the Axial Complex Shaped Defect in a Pressurized Pipe
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4052851
dc.journal.fristpage41305-1
dc.journal.lastpage41305-11
dc.page11
dc.treeJournal of Pressure Vessel Technology:;2021:;volume( 144 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record