Show simple item record

dc.contributor.authorGebai, Sarah
dc.contributor.authorCumunel, Gwendal
dc.contributor.authorHammoud, Mohammad
dc.contributor.authorForet, Gilles
dc.contributor.authorRoze, Emmanuel
dc.contributor.authorHainque, Elodie
dc.date.accessioned2022-05-08T08:37:50Z
dc.date.available2022-05-08T08:37:50Z
dc.date.copyright3/30/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_09_091003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284148
dc.description.abstractTremor is a semirhythmic oscillatory movement of a body part caused by alternating simultaneous contractions of an antagonistic muscle group. Medical and surgical treatments used to reduce the symptoms of involuntary tremor can cause negative side effects. This study examined the ability of passive vibration absorbers in reducing the amplitude of postural tremor (PT). Inertial measurement unit (IMU) was used to record PT signals at the forearm and hand of a patient. IMU signal was used to excite an upper limb modeled to represent the flexion–extension vibrational motion at the joints. Equations of motion were solved numerically to obtain a response that fits the measured tremor signal. Passive tuned mass damper (TMD) was modeled as a cantilever beam and a screw placed along its length, at a position reflecting its operational frequency. Natural frequency of the TMD was derived for different mass positions and validated numerically and experimentally. Modal damping ratio of the TMD, for each mass position, was also estimated. Mass position and damping coefficient of the TMD were optimized depending on the minimization in the power spectral density (PSD) of angular displacement amplitude at the wrist joint. Optimized three-TMD system of 28.64 g total effective mass with the estimated modal damping ratio reduced 83.1% of the PSD of the angular displacement amplitude. This study showed the performance ability of a lightweight passive absorber in controlling the involuntary tremor of a system excited by the measured tremor signal of a patient.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign and Simulation of a Passive Absorber to Reduce Measured Postural Tremor Signal
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue9
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053998
dc.journal.fristpage91003-1
dc.journal.lastpage91003-13
dc.page13
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record