Show simple item record

dc.contributor.authorIbba, Miriam
dc.contributor.authorPesetti, Alessio
dc.contributor.authorRaucci, Michele
dc.contributor.authorParozzi, Flavio
dc.contributor.authorLazzeri, Roberta
dc.contributor.authorAquaro, Donato
dc.date.accessioned2022-05-08T08:32:43Z
dc.date.available2022-05-08T08:32:43Z
dc.date.copyright3/16/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn2332-8983
dc.identifier.otherners_008_04_042301.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284064
dc.description.abstractThis paper deals with an experimental and numerical analysis of the deposition of International thermonuclear experimental reactor (ITER) dust simulant inside a reduced scale vacuum vessel pressure suppression system (VVPSS) of ITER. This research, funded by the ITER organization, aims to analyze the dust deposition in a water container in a relevant configuration for the ITER VVPSS, the dust removal by means of robotized apparatuses and their decontamination efficiency. The experimental rig, built at the department of civil and industrial engineering (DICI) of the University of Pisa (Italy), is described and the results of a preliminary experimental test are illustrated. It was measured that two and 82% of the overall injected dust mass was strongly and lightly bound to the water container surfaces, respectively, and 16% were not deposited in the water tank. Furthermore, three numerical analyses were carried out implementing a model of the experimental rig in the Enel code for analysis of radionuclide transport (ECART) to determine the relevance of different parameters on the deposition, resuspension and removal of dust. The numerical simulations allowed to specify dust mass deposition on the different rig components, revealing a strong dust retention (about 66%) in the first part of the injection piping in case of coarse granulometry. Finest lognormal dust distribution was instead able to reach the water container (about 90%). Moreover, the numerical simulations permitted to define more precisely the test matrix and to analyze the experimental results.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDeposition of ITER Vacuum Vessel Dust Inside the Pressure Suppression System During a Loss of Coolant Accident: Experimental and Numerical Analyses
dc.typeJournal Paper
dc.journal.volume8
dc.journal.issue4
dc.journal.titleJournal of Nuclear Engineering and Radiation Science
dc.identifier.doi10.1115/1.4050768
dc.journal.fristpage42301-1
dc.journal.lastpage42301-7
dc.page7
dc.treeJournal of Nuclear Engineering and Radiation Science:;2022:;volume( 008 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record