dc.contributor.authorKümmerlin, Jana
dc.contributor.authorFabro, Hannah Katharina
dc.contributor.authorPedersen, Peter Heide
dc.contributor.authorJensen, Kenneth Krogh
dc.contributor.authorPedersen, Dennis
dc.contributor.authorAndersen, Michael Skipper
dc.date.accessioned2022-05-08T08:32:33Z
dc.date.available2022-05-08T08:32:33Z
dc.date.copyright3/4/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_08_084502.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284059
dc.description.abstractAccurate and reliable information about three-dimensional (3D) knee joint laxity can prevent misdiagnosis and avoid incorrect treatments. Nevertheless, knee laxity assessments presented in the literature suffer from significant drawbacks such as soft tissue artifacts, restricting the knee within the measurement, and the absence of quantitative knee ligament property information. In this study, we demonstrated the applicability of a novel methodology for measuring 3D knee laxity, combining robotics- and image-based technology. As such technology has never been applied to healthy living subjects, the aims of this study were to develop novel technology to measure 3D knee laxity in vivo and to provide proof-of-concept 3D knee laxity measurements. To measure tibiofemoral movements, four healthy subjects were placed on a custom-built arthrometer located inside a low dose biplanar X-ray system with an approximately 60 deg knee flexion angle. Anteroposterior and mediolateral translation as well as internal and external rotation loads were subsequently applied to the unconstrained leg, which was placed inside a pneumatic cast boot. Bone contours were segmented in the obtained X-rays, to which subject-specific bone geometries from magnetic resonance imaging (MRI) scans were registered. Afterward, tibiofemoral poses were computed. Measurements of primary and secondary laxity revealed considerable interpersonal differences. The method differs from those available by the ability to accurately track secondary laxity of the unrestricted knee and to apply coupled forces in multiple planes. Our methodology can provide reliable information for academic knee ligament research as well as for clinical diagnostics in the future.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleMeasuring Knee Joint Laxity in Three Degrees-of-Freedom In Vivo Using a Robotics- and Image-Based Technology
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue8
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053792
dc.journal.fristpage84502-1
dc.journal.lastpage84502-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 008