    Carpal tunnel syndrome and tendonitis are two common upper extremity cumulative trauma disorders (CTD) related to repetitive and forceful activities in industrial environments. Reducing the muscular force during activities such as the operation of a pistol grip hand tool could result in lower incidence of CTDs. The objective of this research was to reduce the muscular contribution to the grip force using an active grasp assist orthosis system. A novel soft, pneumatic grasp assistive device was designed to augment the users' strength during operation of pistol grip hand tool. The optimized design was fabricated using rapid prototyping. Device effectiveness was quantified by measuring muscle activity and grip force during an in vivo study of a common industrial activity. Nine subjects experienced with power tools employed by an automobile manufacturer installed 18 fasteners using a pistol grip DC tool with and without the grasp assistive device. Surface electromyography (sEMG) was used to measure the activity of four muscles commonly associated with grasping. The grasp assist significantly reduced the mean, combined, normalized muscle activity by 18% (p&lt
     
    0.05). Muscle activation results were contextualized using the revised strain index (RSI). The grasp assistive device trial yielded a significantly lower mean RSI value than the typical trial by 13% (p&lt
     
    0.05). Using an active grasp assist orthosis could reduce the incidence of CTDs in able bodied industrial workers using DC hand tools. The device used a unique design of sinusoidal bellows oriented at 45 deg to the plane of symmetry that yielded higher force output and a lower bending ratio and lower input pressure with acceptable device rigidity and strength.
     
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283976
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV