    Inexpensive Multipatient Respiratory Monitoring System for Helmet Ventilation During COVID-19 Pandemic

    Thumbnail
    View/Open
    med_016_01_011003.pdf (5.289Mb)
    Date
    2022
    Author
    The Princeton Open Ventilation Monitor Collaboration
    Bourrianne, Philippe
    Chidzik, Stanley
    J. Cohen, Daniel
    Elmer, Peter
    Hallowell, Thomas
    Kilbaugh, Todd J.
    Lange, David
    Leifer, Andrew M.
    Marlow, Daniel R.
    Meyers, Peter D.
    Normand, Edna
    Nunes,
    Metadata
    Show full item record
    Abstract
    Helmet continuous positive applied pressure is a form of noninvasive ventilation (NIV) that has been used to provide respiratory support to COVID-19 patients. Helmet NIV is low-cost, readily available, provides viral filters between the patient and clinician, and may reduce the need for invasive ventilation. Its widespread adoption has been limited, however, by the lack of a respiratory monitoring system needed to address known safety vulnerabilities and to monitor patients. To address these safety and clinical needs, we developed an inexpensive respiratory monitoring system based on readily available components suitable for local manufacture. Open-source design and manufacturing documents are provided. The monitoring system comprises flow, pressure, and CO2 sensors on the expiratory path of the helmet circuit and a central remote station to monitor up to 20 patients. The system is validated in bench tests, in human-subject tests on healthy volunteers, and in experiments that compare respiratory features obtained at the expiratory path to simultaneous ground-truth measurements from proximal sensors. Measurements of flow and pressure at the expiratory path are shown to deviate at high flow rates, and the tidal volumes reported via the expiratory path are systematically underestimated. Helmet monitoring systems exhibit high-flow rate, nonlinear effects from flow and helmet dynamics. These deviations are found to be within a reasonable margin and should, in principle, allow for calibration, correction, and deployment of clinically accurate derived quantities.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283969
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV