• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Novel and Inexpensive Technique for High-Tension Tendon Clamping With Expandable Mesh Sleeving for In Vitro Foot Biomechanics Testing

    Thumbnail
    View/Open
    bio_144_07_074501.pdf (1.048Mb)
    Date
    2022
    Author
    Golubovsky, Joshua L.
    Gillespie, Callan M.
    Nagle, Tara F.
    Loss, Jeremy G.
    Colbrunn, Robb W.
    Metadata
    Show full item record
    Abstract
    In vitro biomechanical testing is common in the field of orthopedics when novel devices are investigated prior to human trials. It is typically necessary to apply loads through tendons to simulate normal activities, such as walking during a foot and ankle study. However, attachment of tendons to linear actuators has proven challenging because of the tendency of clamps to either slip off or rupture the tendon. Various techniques have been utilized. Freeze clamping is generally accepted as the gold standard for very high load testing in excess of 3000 N, but is expensive, time-consuming, and requires significant ancillary equipment. Purely mechanical solutions such as metal jaw clamps, wire meshes, and others have been explored, but these techniques are either costly, have low load capacities, or have not proven to be reproducible. We have developed a novel tendon clamping technique that utilizes a slip-resistant polyester mesh sleeving that encases the tendon and is fixated at the bottom of the tendon/sleeve interaction with a giftbox suture. The loose end of the sleeving can then be tied in to the linear actuator or load cell apparatus using a timber hitch knot. The sleeving technique allows for loads of 2000–2500 N on the Achilles tendon, and is inexpensive, reproducible, and can be modified to apply loads to smaller tendons as well, though a length of tendon/sleeve overlap of at least 16 cm is required to reach maximum loads. This technique should assist researchers in integrating muscle forces into future biomechanical study designs.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283859
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV