Show simple item record

dc.contributor.authorBons, Zachary
dc.contributor.authorDickinson, Taylor
dc.contributor.authorClark, Ryan
dc.contributor.authorBeardsley, Kari
dc.contributor.authorCharles, Steven K.
dc.date.accessioned2022-05-08T08:19:03Z
dc.date.available2022-05-08T08:19:03Z
dc.date.copyright2/18/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_07_071007.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283793
dc.description.abstractMost motion capture measurements suffer from soft-tissue artifacts (STA). Especially affected are rotations about the long axis of a limb segment, such as humeral internal-external rotation (HIER) and forearm pronation-supination (FPS). Unfortunately, most existing methods to compensate for STA were designed for optoelectronic motion capture systems. We present and evaluate an STA compensation method that (1) compensates for STA in HIER and/or FPS, (2) is developed specifically for electromagnetic motion capture systems, and (3) does not require additional calibration or data. To compensate for STA, calculation of HIER angles relies on forearm orientation, and calculation of FPS angles rely on hand orientation. To test this approach, we recorded whole-arm movement data from eight subjects and compared their joint angle trajectories calculated according to progressive levels of STA compensation. Compensated HIER and FPS angles were significantly larger than uncompensated angles. Although the effect of STA compensation on other joint angles (besides HIER and FPS) was usually modest, significant effects were seen in certain degrees-of-freedom under some conditions. Overall, the method functioned as intended during most of the range of motion of the upper limb, but it becomes unstable in extreme elbow extension and extreme wrist flexion–extension. Specifically, this method is not recommended for movements within 20 deg of full elbow extension, full wrist flexion, or full wrist extension. Since this method does not require additional calibration of data, it can be applied retroactively to data collected without the intent to compensate for STA.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCompensating for Soft-Tissue Artifact Using the Orientation of Distal Limb Segments During Electromagnetic Motion Capture of the Upper Limb
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue7
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053366
dc.journal.fristpage71007-1
dc.journal.lastpage71007-14
dc.page14
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record