• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Irrigation and Drainage Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Irrigation and Drainage Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of Pulsating Pressure and Emitter Position in Preventing Drip Emitters from Clogging

    Thumbnail
    View/Open
    (ASCE)IR.1943-4774.0001658.pdf (895.9Kb)
    Date
    2021-12-20
    Author
    Caio Nascimento Fernandes
    João Carlos Cury Saad
    Metadata
    Show full item record
    Abstract
    Non–pressure compensating (Non-PC) emitters are employed mainly in drip irrigation systems due to their structural simplicity and low manufacturing costs; however, they present high sensitivity to physical obstruction, even when using filtration. This research aimed to analyze the effects of pulsating pressure, constant pressure, and water exit position in terms of preventing clogging in Non-PC drippers with a labyrinth system. The tests were performed on a test bench, and each treatment had 68 drippers (repetitions). Quartz sand was added to the irrigation water at a 500  mg L−1 concentration in two granulometric ranges (53–105 and 250–500 μm) to reproduce field conditions. The performance indicators were emitter flow rate (L h−1) and relative flow rate (qr). For the 250–500 μm granulometric range and the emitters positioned with the water exit facing downward, the 30 s constant pressure and 1 min pulsating pressure resulted in the obstruction of all emitters with only 2 h of operation. In the 53–105 μm granulometric range with the emitter hole facing downward, a pulsating pressure with a 1 min cycle was the most efficient at delaying emitter clogging, showing qr>75% during the first 16 h of operation. When the dripper exit was positioned facing upward in the most critical situation (constant pressure), no clogging was observed within the two granulometric ranges during the 40 h test. For this emitter model, which is widely applied in horticulture, a water exit facing upward is recommended to prevent clogging by suspended solid particles.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283787
    Collections
    • Journal of Irrigation and Drainage Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV