dc.description.abstractIn this paper, upper bound limit analysis that includes a horizontal pseudostatic seismic force is used for the first time to obtain the limit load on strip footings seated on cohesive-frictional soils reinforced with a single geosynthetic layer. Reinforcement tensile rupture and sliding failure modes for the geosynthetic layer are included in the analyses. Results of analyses are presented as optimum reinforcement depths and a bearing capacity equation with a single term and different bearing capacity factors for tensile rupture and sliding failure modes. The bearing capacity factors are presented in tables and capture the combined influence of the reinforcement strength, soil frictional strength and cohesion, soil unit weight, footing geometry, uniform surcharge, and magnitude of horizontal ground acceleration.
dc.publisherASCE
dc.titleSeismic Bearing Capacity of Geosynthetic Reinforced Strip Footings Using Upper Bound Limit Analysis
dc.typeJournal Paper
dc.journal.volume22
dc.journal.issue3
dc.journal.titleInternational Journal of Geomechanics
dc.identifier.doi10.1061/(ASCE)GM.1943-5622.0002292
dc.journal.fristpage04021300
dc.journal.lastpage04021300-13
dc.page13
dc.treeInternational Journal of Geomechanics:;2022:;Volume ( 022 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record