Show simple item record

dc.contributor.authorHesam Bazargan Harandi
dc.contributor.authorAnahita Asadi
dc.contributor.authorZuguo Shen
dc.contributor.authorPang-Chieh Sui
dc.date.accessioned2022-05-07T21:06:08Z
dc.date.available2022-05-07T21:06:08Z
dc.date.issued2022-01-31
dc.identifier.other(ASCE)EY.1943-7897.0000825.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283328
dc.description.abstractTwo hybrid systems, i.e., an integrated flat-plate collector (FPC) and direct contact membrane distillation (DCMD) system and an integrated proton exchange membrane fuel cell (PEMFC) and DCMD system, are proposed to mitigate the negative effects of conventional heat supply methods such as burning fossil fuels. In addition to benefiting from renewable and clean sources, harvesting the waste heat of PEMFCs helps enhance its total efficiency. The proposed FPC-DCMD and PEMFC-DCMD hybrid systems were simulated to evaluate their performance on representative days in the city of Wuhan, China. A new approach that combines two programming environments is demonstrated, i.e., a programmed engineering equation solver code for DCMD modeling and the TRNSYS version 16.0 (2016) software for the dynamic simulation of hybrid systems. The driving force required by DCMD (8,457  kJ/h) is supplied using the two proposed heat supply scenarios to produce 77.4  kg/m2 h of freshwater. The results of the integrated FPC-DCMD system show that the maximum amount of energy supplied by the FPC are 5,919  kJ/h and 2,490  kJ/h at 2 PM during the summer and winter solstices, whereas the amounts of energy provided by the auxiliary heater are 2,537  kJ/h and 5,967  kJ/h, respectively. The average solar fraction at the summer solstice was 19%, whereas at 2 PM, the integrated FPC-DCMD system can provide approximately 70% of the total energy required at the maximum mode. In another scenario, 6,185  kJ/h of the total energy required for DCMD was supplied by harvesting the waste heat of the PEMFC, whereas the rest was provided by an auxiliary electric heater. It was found that 73% of the total energy required by DCMD to increase the feed water inlet temperature from 25°C to 80°C was obtained by harvesting the waste heat of the PEMFC.
dc.publisherASCE
dc.titleIntegration of Direct-Contact Membrane Distillation with Flat-Plate Solar Collector versus Proton-Exchange Membrane Fuel Cell: Dynamic Simulations and Comparative Analysis
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue2
dc.journal.titleJournal of Energy Engineering
dc.identifier.doi10.1061/(ASCE)EY.1943-7897.0000825
dc.journal.fristpage04022005
dc.journal.lastpage04022005-15
dc.page15
dc.treeJournal of Energy Engineering:;2022:;Volume ( 148 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record