Show simple item record

dc.contributor.authorJustine E. Gleason
dc.contributor.authorDaniel Burbes
dc.contributor.authorOlya S. Keen
dc.date.accessioned2022-05-07T20:59:45Z
dc.date.available2022-05-07T20:59:45Z
dc.date.issued2021-12-31
dc.identifier.other(ASCE)EE.1943-7870.0001975.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283170
dc.description.abstractThis study explored mineral catalysts for H2O2 quenching after UV/H2O2 advanced oxidation as an alternative to granular activated carbon or chlorine (two of the most common methods). The following mineral catalysts were evaluated in batch reactors: activated alumina, aluminum oxide, iron (III) oxide, titanium dioxide, titanium, silver, zinc, and magnesium oxide. Of these, aluminum oxide and iron (III) oxide were the most promising catalysts and were further tested in column studies and compared with granular activated carbon (GAC). Aluminum oxide performance in column studies was inferior to the results obtained from GAC and iron (III) oxide, possibly due to the hygroscopic nature of the material. Additional rapid small-scale column tests (RSSCTs) were conducted with iron (III) oxide to mimic a three-year full-scale column operation and achieved 90%–99% removal of H2O2. The decomposition of H2O2 on the catalytic surface appears to generate hydroxyl radicals, although not at a sufficient level to provide considerable additional contaminant destruction after advanced oxidation. The process did not elevate iron concentration in the treated water to a level above the secondary USEPA standard of 0.3  mg/L (0.12  mg/L maximum, 0.03  mg/L average). Longer-term pilot-scale study is necessary to determine operational requirements, such as backwashing, and to determine whether the observed loss of activity over time can be regenerated. Overall, the process appears to be a viable option for H2O2 quenching, making application of UV/H2O2 advanced oxidation more practical for drinking water treatment where residual H2O2 can interfere with chlorination.
dc.publisherASCE
dc.titleHydrogen Peroxide Quenching with Mineral Catalysts after UV/H2O2 Advanced Oxidation
dc.typeJournal Paper
dc.journal.volume148
dc.journal.issue3
dc.journal.titleJournal of Environmental Engineering
dc.identifier.doi10.1061/(ASCE)EE.1943-7870.0001975
dc.journal.fristpage04021089
dc.journal.lastpage04021089-7
dc.page7
dc.treeJournal of Environmental Engineering:;2021:;Volume ( 148 ):;issue: 003
dc.contenttypeFulltext