Show simple item record

dc.contributor.authorShen-En Chen
dc.contributor.authorSophia Lin
dc.contributor.authorChin-Tung Cheng
dc.contributor.authorSusmita Bhowmik
dc.contributor.authorWenwu Tang
dc.contributor.authorYamilka Baez-Rivera
dc.contributor.authorRicardo Martinez
dc.date.accessioned2022-05-07T20:50:32Z
dc.date.available2022-05-07T20:50:32Z
dc.date.issued2022-01-25
dc.identifier.other(ASCE)CF.1943-5509.0001708.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282981
dc.description.abstractThis paper reports an assessment of structure damages after the Richter magnitude 6.4 Puerto Rico earthquake that occurred on January 7, 2020. A review of the seismicity of the region and the postdisaster investigation of structural damages is first presented. The paper then focuses on explaining the failure modes of 2-story residential structures with open first story, which demonstrated the classical soft story behavior. The typological characterization of the failure modes is investigated using a nonlinear elastic dynamic analysis with a single degree of freedom model, which illustrates the contributions from partial to full construction of infill walls to the stiffness of the 2-story structures. The results indicate that the completion of the infill walls can significantly improve the stiffness of these structures and reduce damages to the structures.
dc.publisherASCE
dc.titleTwo-Story Residential Structure Damages after the 2020 Puerto Rico Earthquake
dc.typeJournal Paper
dc.journal.volume36
dc.journal.issue2
dc.journal.titleJournal of Performance of Constructed Facilities
dc.identifier.doi10.1061/(ASCE)CF.1943-5509.0001708
dc.journal.fristpage04022006
dc.journal.lastpage04022006-16
dc.page16
dc.treeJournal of Performance of Constructed Facilities:;2022:;Volume ( 036 ):;issue: 002
dc.contenttypeFulltext


Files in this item