• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental and Numerical Study of Near-Fault Seismic Performance of 2-Story Steel Framed Building with Self-Centering Modular Panels

    Thumbnail
    View/Open
    (ASCE)ST.1943-541X.0003359.pdf (4.245Mb)
    Date
    2022-04-08
    Author
    Gongling Chu
    Wei Wang
    Yunfeng Zhang
    Metadata
    Show full item record
    Abstract
    This paper presents the full-scale shake-table test and numerical simulation study results of a 2-story beam-through steel frame (BTSF) equipped with self-centering modular panels (SCMPs) subjected to near-fault ground motion records. A SCMP is a portable self-centering device that can be inserted and bolted to steel frames to provide lateral force resistance with recentering capability and replaceable seismic fuse devices for energy dissipation. Previous research works have been done on the analytical study, quasi-static cyclic loading testing, and numerical study of the general seismic behavior of the SCMP systems with different energy dissipation components including tension-only braces, slit steel plate shear walls (SWs), and hysteretic dampers. An important aim of this study is to experimentally verify the seismic performance of full-scale steel frame structures with SCMPs via shaking-table tests capable of applying pulselike ground motion. A literature review of previous research works suggested that near-fault ground motions can amplify the dynamic response of structures and cause more extensive damage compared with far-fault ground motion records. To achieve this goal of studying the effect of near-fault ground motion records on the test structure installed with SCMPs, a nonlinear finite-element (FE) model has been developed for a parametric study in which a set of near-fault ground motion records were used as base excitation to the structure model. The nonlinear dynamic analysis results showed that the test structure exhibited self-centering capability under both design-basis earthquake (DBE) and maximum considered earthquake (MCE) cases. Additionally, the effect of energy dissipation capacity on the test structure’s response is also discussed.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282489
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV