• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Study of Continuous-Beam Lateral Torsional–Buckling Resistance with a Noncomposite Concrete Deck

    Thumbnail
    View/Open
    (ASCE)ST.1943-541X.0003301.pdf (2.095Mb)
    Date
    2022-02-10
    Author
    Chuanbing “Shawn” Sun
    Daniel G. Linzell
    Jay A. Puckett
    Emmanuel Akintunde
    Ahmed Rageh
    Metadata
    Show full item record
    Abstract
    Some of Louisiana’s bridges built in the 1950s and 1960s used two-girder or truss systems, in which transverse floor beams are carried by main longitudinal members and continuous (spliced) beams supporting the deck are supported by the floor beams. The main longitudinal members are either two edge (fascia) girders or trusses. Continuous-beam bottom flanges are in compression in the negative moment region, which could result in lateral torsional buckling. When the continuous beams are load rated, Cb is calculated in accordance with a standard specification that does not account for potentially beneficial bracing effects from a noncomposite concrete deck and could therefore underestimate actual flexural strength. As a result, the rating may require a restrictive bridge posting or closure. This issue affects bridges that are key parts of Louisiana’s highway system, i.e., longer, multispan crossings with high average daily traffic (ADT) counts. The calculated load rating could require expensive, and possibly unnecessary, bridge rehabilitation or replacement with significant traffic disruption. This research reassessed the methodology behind load rating these continuous beams, with efforts focusing on deriving more realistic values for Cb. Its main objective was to evaluate the capacity of bridges built with continuous beams and noncomposite decks and to develop a new approach for rating those beams by more accurately representing the moment gradients using Cb. An experimental study was conducted to evaluate lateral torsional–buckling resistance of a reduced-scale, two-span grillage system that included three lines of continuous beams supporting a noncomposite concrete deck. A significantly higher moment gradient factor as compared to the existing codes and standards was recommended by accounting for the bracing effect provided by a noncomposite deck.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282437
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV