• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Collaborative Experience: Implementation of an Optimized Tc-99m Generator Assembly Process

    Thumbnail
    View/Open
    ners_007_04_042008.pdf (722.8Kb)
    Date
    2021
    Author
    Sharma, Rijata
    Sial, Bronte
    Lake, Henry
    Maharaj, Prashant
    Reus-Smit, Joshua
    Popp, Andrew
    Metadata
    Show full item record
    Abstract
    Technetium-99m (Tc-99m) has a 6-hr half-life making customer transportation times a challenge. Australian Nuclear Science and Technology Organization (ANSTO) health products group has overcome this by delivering the parent isotope molybdenum-99 (Mo-99), which has a half-life of 66 hr, in shielded GENTECH™ generators. As part of ANSTO's questioning attitude, an augmented risk assessment was undertaken to identify any potential exposure risks of the GENTECH™ assembly process. The evaluation identified potential areas of improvement in contamination control for the manual handling of the generator leads. Upon further analysis, contamination events from the generator leads had the potential for skin doses above the threshold for skin tissue reactions. Additional substitution and administrative controls were designed to mitigate the risks identified. The effectiveness of the new controls was assessed for efficiency in the manufacturing process through mock trials and fitness for use in a pharmaceutical cleanroom environment. The implemented controls were monitored, and data from each run were gathered. These data included changes in radiological conditions and dosimetry results. Upon implementation, there was an observable decrease in glove contamination. The decrease verified that there was a reduction in the risk of skin contamination events. The data analysis was used to model the dose averted, which revealed a reduction in potential extremity dose to production workers. This paper aims to show the optimization within an approved process through the implementation of engineering and administrative controls, resulting in a dose reduction to workers.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278784
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV