• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Using Smartphones for Clinical Assessment in Cervical Spondylotic Myelopathy a Feasibility Study

    Thumbnail
    View/Open
    med_015_04_044503.pdf (2.247Mb)
    Date
    2021
    Author
    Zaldivar-Jolissaint, Julien Francisco
    Lechanoine, François
    Krummenacher, Bernard
    Arruda, Rivus Ferreira
    Bobinski, Lukas
    Schlichting, Emmanuel de
    Duff, John Michael
    Metadata
    Show full item record
    Abstract
    Degenerative cervical myelopathy (DCM) is characterized by a progressive deterioration in spinal cord function. Its evaluation requires subjective clinical examination with wide interobserver variability. Objective quantification of spinal cord function remains imprecise, even though validated myelopathy-grading scales have emerged and are now widely used. We created a Smartphone Application, the N-Outcome App, with the aim of quantifying accurately and reliably spinal cord dysfunction using a 5-minute Test. A patient suffering from DCM was clinically evaluated before surgery, at 3 and 6 months follow-up after surgical decompression of the cervical spinal cord. Standard scores (Nurick grade, modified Japanese Orthopedic Association (mJOA) score) were documented at these time points. A 5-minute motor and proprioceptive performance test aided by a smartphone with the N-outcome App was also performed. Motor performance in rapid alternating movements and finger tapping improved in correlation with improvements in standard grading scale scores. Clinical improvements were seen in maximum reflex acceleration and in Romberg testing which showed less closed/open eyes variation, suggesting pyramidal and proprioceptive function recovery. We demonstrate that using the N-Outcome App as an adjunct to clinical evaluation of compressive myelopathy is feasible and potentially useful. The results correlate with the results of clinical assessment obtained by standard validated myelopathy scores.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278751
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV