Show simple item record

dc.contributor.authorLei, Shunbo
dc.contributor.authorMathieu, Johanna L.
dc.contributor.authorJain, Rishee K.
dc.date.accessioned2022-02-06T05:40:18Z
dc.date.available2022-02-06T05:40:18Z
dc.date.copyright5/14/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn2642-6641
dc.identifier.otherjesbc_2_2_021002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278516
dc.description.abstractCommercial buildings generally have large thermal inertia and thus can provide services to power grids (e.g., demand response (DR)) by modulating their heating, ventilation, and air conditioning (HVAC) systems. Shifting consumption on timescales of minutes to an hour can be accomplished through temperature setpoint adjustments that affect HVAC fan consumption. Estimating the counterfactual baseline power consumption of HVAC fans is challenging but is critical for assessing the capacity and participation of DR from HVAC fans in grid-interactive efficient buildings (GEBs). DR baseline methods have been developed for whole-building power profiles. This study evaluates those methods on total HVAC fan power profiles, which have different characteristics than whole-building power profiles. Specifically, we assess averaging methods (e.g., Y-day average, HighXofY, and MidXofY, with and without additive adjustments), which are the most commonly used in practice, and a least squares-based linear interpolation method recently developed for baselining HVAC fan power. We use empirical submetering data from HVAC fans in three University of Michigan buildings in our assessment. We find that the linear interpolation method has a low bias and by far the highest accuracy, indicating that it is potentially the most effective existing baseline method for quantifying the effects of short-term load shifting of HVAC fans. Overall, our results provide new insights on the applicability of existing DR baseline methods to baselining fan power and enable the more widespread contribution of GEBs to DR and other grid services.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePerformance of Existing Methods in Baselining Demand Response From Commercial Building HVAC Fans
dc.typeJournal Paper
dc.journal.volume2
dc.journal.issue2
dc.journal.titleASME Journal of Engineering for Sustainable Buildings and Cities
dc.identifier.doi10.1115/1.4050999
dc.journal.fristpage021002-1
dc.journal.lastpage021002-13
dc.page13
dc.treeASME Journal of Engineering for Sustainable Buildings and Cities:;2021:;volume( 002 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record