    A Parametric Analysis of Embedded Tissue Marker Properties and Their Effect on the Accuracy of Displacement Measurements

    Thumbnail
    View/Open
    bio_143_11_111011.pdf (2.054Mb)
    Date
    2021
    Author
    Dutrisac, Scott
    Brannen, MacKenzie
    Hoshizaki, T. Blaine
    Frei, Hanspeter
    Petel, Oren E.
    Metadata
    Show full item record
    Abstract
    Datasets obtained from cadaveric experimentation are broadly used in validating finite element models of head injury. Due to the complexity of such measurements in soft tissues, experimentalists have relied on tissue-embedded radiographic or sonomicrometry tracking markers to resolve tissue motion caused by impulsive loads. Dynamic coupling of markers with the surrounding tissue has been a previous concern, yet a thorough sensitivity investigation of marker influences on tissue deformation has not been broadly discussed. Technological improvements to measurement precision have bolstered confidence in acquired data; however, precision is often conflated with accuracy; the inclusion of markers in the tissue may alter its natural response, resulting in a loss of accuracy associated with an altered displacement field. To gain an understanding of how marker properties may influence the measured response to impact, we prepared a set of nine marker designs using a Taguchi L9 array to investigate marker design choice sensitivity. Each of these designs was cast into a block of tissue simulant and subjected to repeated drop tests. Vertical displacement was measured and compared to the response of the neat material, which contained massless tracking markers. Medium density and medium stiffness markers yielded the least deviation from the neat material response. The results provide some design guidelines indicating the importance of maintaining marker matrix density ratio below 1.75 and marker stiffness below 1.0 MPa. These properties may minimize marker interference in tissue deformation. Overall, embedded marker properties must be considered when measuring the dynamic response of tissue.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278508
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV