Show simple item record

dc.contributor.authorRout, Anil Kumar
dc.contributor.authorSahoo, Niranjan
dc.contributor.authorKalita, Pankaj
dc.date.accessioned2022-02-06T05:33:24Z
dc.date.available2022-02-06T05:33:24Z
dc.date.copyright4/23/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn0022-1481
dc.identifier.otherht_143_06_062901.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278274
dc.description.abstractThe measurement of surface temperatures in highly unsteady flow environments is a challenging task pertaining to the need for high-frequency sensors. This paper contains the sequential activities related to a fast response thermal probe (coaxial surface junction probe—CSJP). This probe is prepared in the laboratory, and its salient features are explored for short-duration (∼20 ms) experiments. The surface junction morphology and inside texture of the probe are examined under field emission scanning electron microscope (FESEM). The study confirms the plastic deformation of thermo-elements with an average junction thickness of 21 μm. The static calibration of the probe using a glycerin bath shows a linear trend between voltage and temperature from which the sensitivity value is calculated as 59 μV/°C. The “thermal product” of the probe is also measured experimentally through the “water droplet technique,” and its value is found to be 8677 J/m2 s0.5 K. The concept of one-dimensional heat flux modeling is followed to infer surface heat flux from transient temperatures. For assuring prediction of heat flux, the probe is calibrated experimentally by exposing to a laser source of known wattage (2 W and 3 W). These findings are also supported by numerical simulation of the probe with accuracy in prediction for surface temperature and heat flux as  ± 2% and ±3%, respectively. The performance capability of the probe is demonstrated through shock-tube flow experiments to measure instantaneous heat flux. The comparison of the transient response behavior (9500 K/s) with pressure transducer justifies the utility of the probe under hostile flow environment.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTransient Response Characteristics and Performance Assessment of a Calorimetric Surface Junction Probe Under Impulsive Thermal Loading
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue6
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4050822
dc.journal.fristpage062901-1
dc.journal.lastpage062901-11
dc.page11
dc.treeJournal of Heat Transfer:;2021:;volume( 143 ):;issue: 006
dc.contenttypeFulltext