Show simple item record

dc.contributor.authorSciancalepore, Annalisa
dc.contributor.authorVacca, Andrea
dc.contributor.authorWeber, Steven
dc.date.accessioned2022-02-06T05:27:10Z
dc.date.available2022-02-06T05:27:10Z
dc.date.copyright8/13/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn0022-0434
dc.identifier.otherds_143_11_111007.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278055
dc.description.abstractCounterbalance valves (CBVs) are widely used in hydraulic machines handling gravitational loads. They are usually adopted in hydraulic circuits that set the flow to the actuator with either metering control strategies or primary control strategies. In these circuits, the CBV does not determine the actuator velocity, but it establishes a proper counterpressure that balances the actuator during overrunning loads. A well-known problem of CBVs is the excessive power consumption introduced into the circuit, which is due to an excessive pressurization of the flow supply. This paper presents a solution for using CBVs to control the actuator velocity while also reducing energy consumption. The method consists in controlling the pilot port of the CBV through an external pressure source (adjustable pilot). The solution is first studied analytically, considering all the possible loading conditions at the actuator. Two different control strategies are presented: the “Smart CBV,” where the CBV does not control the actuator velocity but it minimizes the system pressure; and the “Smart System” that uses the CBV to efficiently control the actuator velocity during overrunning load conditions. An experimental validation of the proposed solutions is also provided, taking as reference a truck-mounted hydraulic crane. The results of the proposed solutions are compared to those achieved by the traditional circuit of the reference hydraulic crane which uses standard CBVs. For both cases of smart CBV and smart system, a remarkable power saving, respectively, up to 75% and up to 90% is observed.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAn Energy-Efficient Method for Controlling Hydraulic Actuators Using Counterbalance Valves With Adjustable Pilot
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue11
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.4051643
dc.journal.fristpage0111007-1
dc.journal.lastpage0111007-18
dc.page18
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2021:;volume( 143 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record