dc.description.abstractMicroscale holes were punched at cryogenic conditions in polycaprolactone (PCL) membranes to create synthetic three-dimensional (3D) tissue scaffolds through multilayer stacking of two-dimensional (2D) porous membranes. Punching forces were experimentally measured, and finite element modeling of the punching process was validated by comparing punching force results. Holes of nominal diameter of 200 μm were punched in PCL films of two different thicknesses: 40 μm and 70 μm. Die clearances used for holes in 40 μm thick films were 15.0%, 30.0%, and 45.0%. Die clearances used for holes in 70 μm films were 8.6%, 17.1%, and 25.7%. All holes were punched while the PCL film was in thermal equilibrium with a bath of boiling liquid nitrogen. Punching forces were analyzed to study the effect of die clearance and film thickness. A 3D finite element simulation of the punching process was done using deform 3d software. Cryogenic material properties of PCL used in the simulation were determined experimentally. It was concluded that finite element simulation for the cryogenic micropunching process can be used to predict peak punching forces with reasonable accuracy, which is a key factor to be considered while designing the punching dies. The finite element simulations did not predict an optimal die clearance to minimize peak punching force. However, the measured peak punching forces for 70 μm thick film seem to favor the smallest die clearance to minimize peak punching force.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffect of Die Clearance on Peak Punching Force During Cryogenic Micropunching of Polycaprolactone
dc.typeJournal Paper
dc.journal.volume4
dc.journal.issue1
dc.journal.titleJournal of Engineering and Science in Medical Diagnostics and Therapy
dc.identifier.doi10.1115/1.4049106
dc.journal.fristpage011004-1
dc.journal.lastpage011004-6
dc.page6
dc.treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2020:;volume( 004 ):;issue: 001