    Laboratory Investigation on Oil Increment and Water Cut Control of CO2, N2, and Gas Mixture Huff-n-Puff in Edge-Water Fault-Block Reservoirs

    Thumbnail
    View/Open
    jert_143_8_083001.pdf (1.734Mb)
    Date
    2020
    Author
    Wang, Peng
    Zhao, Fenglan
    Huang, Shijun
    Zhang, Meng
    Feng, Hairu
    Li, Yan
    Song, Liguang
    Metadata
    Show full item record
    Abstract
    Excessive water production is a common matter that seriously affects production efficiency during the development of edge-water fault-block reservoirs. Gas huff-n-puff is an effective water shutoff technology that has the characteristics of small injection volume, no interwell connectivity impact, and minor gas channeling. However, gas injection can destroy the stability of the asphaltene to induce asphaltene deposition. In this article, the laboratory experiment had been conducted to investigate the effect of injection ratio and injection sequence on oil increment and water cut control for gas mixture huff-n-puff. Experimental results indicated that the effect of N2 huff-n-puff on water cut control was the most obvious, while CO2 huff-n-puff had the best performance on oil increment. Oil increment and water cut control of gas mixture huff-n-puff with CO2 injected in advance were obviously better than that of N2 injection preferentially. Subsequently, PVTsim Nova was utilized to investigate whether reducing CO2 injection volume can inhibit asphaltene deposition and predict the possibility of asphaltene deposition at reservoir conditions. Simulation results demonstrated that the asphaltenes were easily deposited with CO2 injection while N2 injection will be unlikely to induce asphaltene deposition. Asphaltene deposition pressure envelope can qualitatively analyze the possibility of asphaltene deposition and provide a reference for screening the appropriate gas injection ratio based on giving full play to the synergistic effect of CO2 and N2. In this study, 7:3 is selected as the optimum injection ratio considering the synergistic effect and the possibility of asphaltene deposition.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277931
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV