Show simple item record

dc.contributor.authorOlesnavage, Kathryn M.
dc.contributor.authorProst, Victor
dc.contributor.authorJohnson, William Brett
dc.contributor.authorMajor, Matthew J.
dc.contributor.authorWinter, Amos G., V
dc.date.accessioned2022-02-05T22:25:11Z
dc.date.available2022-02-05T22:25:11Z
dc.date.copyright12/10/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn0148-0731
dc.identifier.otherbio_143_03_031003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277503
dc.description.abstractWhile many studies have attempted to characterize the mechanical behavior of passive prosthetic feet to understand their influence on amputee gait, the relationship between mechanical design and biomechanical performance has not yet been fully articulated from a fundamental physics perspective. A novel framework, called lower leg trajectory error (LLTE) framework, presents a means of quantitatively optimizing the constitutive model of prosthetic feet to match a reference kinematic and kinetic dataset. This framework can be used to predict the required stiffness and geometry of a prosthesis to yield a desired biomechanical response. A passive prototype foot with adjustable ankle stiffness was tested by a unilateral transtibial amputee to evaluate this framework. The foot condition with LLTE-optimal ankle stiffness enabled the user to replicate the physiological target dataset within 16% root-mean-square (RMS) error. Specifically, the measured kinematic variables matched the target kinematics within 4% RMS error. Testing a range of ankle stiffness conditions from 1.5 to 24.4 N·m/deg with the same user indicated that conditions with lower LLTE values deviated the least from the target kinematic data. Across all conditions, the framework predicted the horizontal/vertical position, and angular orientation of the lower leg during midstance within 1.0 cm, 0.3 cm, and 1.5 deg, respectively. This initial testing suggests that prosthetic feet designed with low LLTE values could offer benefits to users. The LLTE framework is agnostic to specific foot designs and kinematic/kinetic user targets, and could be used to design and customize prosthetic feet.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental Demonstration of the Lower Leg Trajectory Error Framework Using Physiological Data as Inputs
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue3
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4048643
dc.journal.fristpage031003-1
dc.journal.lastpage031003-11
dc.page11
dc.treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 003
dc.contenttypeFulltext