    Study on the Long Bone Failure Behaviors Under the Indenter Rigid-Contact by Experiment Analysis and Subject-Specific Simulation

    Thumbnail
    View/Open
    bio_143_02_021003.pdf (7.514Mb)
    Date
    2020
    Author
    Du, Xianping
    Jiang, Binhui
    Zhang, Guanjun
    Chou, Clifford C.
    Bai, Zhonghao
    Metadata
    Show full item record
    Abstract
    The bending fracture behaviors of long bone have gained great attention due to the high bending fracture risk during sports events, traffic accidents, and falling incidents, etc. For evaluating bone bending behaviors, most of the previous studies used an indenter in three point bending experiments while the effect of its rigidity was never considered. In this work, using the porcine long bones, the three point bending tests were conducted to explore the bone fracture behaviors under a rigid indenter. In addition to collecting the force applied, the bone fracture dynamic process was recorded by high-speed photography, and the fracture surface profile in mesoscale was observed by the scanning electron microscope (SEM). Based on CT scanning of long bones, the cross section properties of test specimens were calculated by a homemade matlab script for correlating with their failure strengths. Also, a subject-specific finite element (FE) model was developed to identify the outcomes induced by a rigid indenter on simulation. Findings led to conclusions as follows: (1) The tension fracture came with fracture path deflection, which was caused by the bone indentation induced mesoscale crack-opening. Due to this damage before the whole bone fracture, a bone fracture moment correction was established to compensate experimental data. (2) The plastic indentation caused the force fluctuation as suggested by correlation analysis. (3) The bone failure moment correlated with the inertial moment of the bone cross section at the fracture location higher than the traditional cross section area. (4) In the subject-specific simulation, the indentation caused compression fracture under a much lower failure force. Removing the element erosion on the indenter-contacted area only during the validation was verified as a good option to solve this issue.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277337
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV