Show simple item record

dc.contributor.authorAlexander Max, Baker
dc.contributor.authorHostetler, Zach
dc.contributor.authorVavalle, Nicholas
dc.contributor.authorArmiger, Robert
dc.contributor.authorCoates, Randolph
dc.contributor.authorGayzik, Francis
dc.date.accessioned2022-02-05T22:18:01Z
dc.date.available2022-02-05T22:18:01Z
dc.date.copyright11/23/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn0148-0731
dc.identifier.otherbio_143_01_014505.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277303
dc.description.abstractInjury due to underbody loading is increasingly relevant to the safety of the modern warfighter. To accurately evaluate injury risk in this loading modality, a biofidelic anthropomorphic test device (e.g., dummy) is required. Finite element model counterparts to the physical dummies are also useful tools in the evaluation of injury risk, but require validated constitutive material models used in the dummy. However, material model fitting can result in models that are over-fit: they match well with the data they were trained on, but do not extrapolate well to new loading scenarios. In this study, we used a hierarchical approach. Material models created from coupon-level tests were evaluated at the component level, and then verified using blinded component and whole body (WB) tests to establish a material model of the anthropomorphic test device (ATD) neck that was not over-fit. Additionally, a combined metric is introduced that incorporates the well-known correlation analysis (CORA) score with peak characteristics to holistically evaluate the material model performance. A Bergstrom Boyce material model fit to one loop of combined compression and tension experimental data performed the best within the training datasets. Its combined metric scores were 2.51 and 2.18 (max score of 3) in a constrained neck and head neck setup, respectively. In the blinded evaluation including flexed, extended, and WB simulations, similar combined scores were observed with 2.44, 2.26, and 2.60, respectively. The agreement between the combined scores in the training and validation dataset indicated that model was not over-fit and can be extrapolated into untested, but similar loading scenarios.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHierarchical Validation Prevents Over-Fitting of the Neck Material Model for an Anthropomorphic Test Device Used in Underbody Blast Scenarios
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue1
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4048706
dc.journal.fristpage014505-1
dc.journal.lastpage014505-11
dc.page11
dc.treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record