• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Influence of Material Model and Aortic Root Motion in Finite Element Analysis of Two Exemplary Cases of Proximal Aortic Dissection

    Thumbnail
    View/Open
    bio_143_01_014504.pdf (3.410Mb)
    Date
    2020
    Author
    Subramaniam, Dhananjay Radhakrishnan
    Gutmark, Ephraim
    Andersen, Niels
    Nielsen, Dorte
    Mortensen, Kristian
    Gravholt, Claus
    Backeljauw, Philippe
    Gutmark-Little, Iris
    Metadata
    Show full item record
    Abstract
    The risk of type-A dissection is increased in subjects with connective tissue disorders and dilatation of the proximal aorta. The location and extents of vessel wall tears in these patients could be potentially missed during prospective imaging studies. The objective of this study is to estimate the distribution of systolic wall stress in two exemplary cases of proximal dissection using finite element analysis (FEA) and evaluate the sensitivity of the distribution to the choice of anisotropic material model and root motion. FEA was performed for predissection aortas, without prior knowledge of the origin and extents of vessel wall tear. The stress distribution was evaluated along the wall tear in the postdissection aortas. The stress distribution was compared for the Fung and Holzapfel models with and without root motion. For the subject with spiral dissection, peak stress coincided with the origin of the tear in the sinotubular junction. For the case with root dissection, maximum stress was obtained at the distal end of the tear. The FEA predicted tear pressure was 20% higher for the subject with root dissection as compared to the case with spiral dissection. The predicted tear pressure was higher (9–11%) for root motions up to 10 mm. The Holzapfel model predicted a tear pressure that was lower (8–15%) than the Fung model. The FEA results showed that both material response and root motion could potentially influence the predicted dissection pressure of the proximal aorta at least for conditions tested in this study.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277292
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV