Show simple item record

dc.contributor.authorKeisar, D.
dc.contributor.authorEilan, B.
dc.contributor.authorGreenblatt, D.
dc.date.accessioned2022-02-05T22:16:09Z
dc.date.available2022-02-05T22:16:09Z
dc.date.copyright2/8/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn0098-2202
dc.identifier.otherfe_143_05_051204.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277243
dc.description.abstractA novel positive displacement, high pressure, vertical axis wind pump (HP-VAWP) was evaluated for the application of stand-alone high-pressure reverse-osmosis desalination and drip irrigation systems. The direct interface between a vertical axis wind turbine (VAWT) and a positive displacement pump that delivers a constant liquid volume per revolution has never been studied before. Understanding the interaction between turbine and pump efficiencies, where delivery pressure is determined by back-pressure alone, is critical for efficient design. Wind tunnel experiments were conducted on a small-scale two-bladed turbine (0.4 m2 cross-sectional area) that operated on a dynamic stall principle. At these small laboratory scales, the turbine and pump peak efficiencies were relatively low (15% and 28%, respectively); nevertheless, the system produced nearly constant pressures in excess of 1.5 bar for a broad operational range. Moreover, the system exhibited a basic self-priming capability, and the turbine could easily be braked by overloading the pump. A conservative field-scale analysis of an HP-VAWP system indicated that a medium-size turbine (12.5 m2 cross-sectional area) could attain a peak efficiency of 12.9%. Realistic efficiencies greater than 20% are attainable, significantly exceeding the 4%–8% typical peak efficiency of the widely used American multibladed wind pumps. Indeed, our research indicates that an HP-VAWP system is viable and requires further development. The benefits of zero carbon emissions during operation, high relative efficiency, and easy manufacturing and maintenance render the HP-VAWP ideal for stand-alone or off-grid environments.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHigh Pressure Vertical Axis Wind Pump
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue5
dc.journal.titleJournal of Fluids Engineering
dc.identifier.doi10.1115/1.4049692
dc.journal.fristpage051204-1
dc.journal.lastpage051204-9
dc.page9
dc.treeJournal of Fluids Engineering:;2021:;volume( 143 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record