    Ultrasonic Wave Propagation Analysis in Cast Stainless Steel With Solidification Grain Structure Predicted by Cellular Automaton Finite Element Approach

    Thumbnail
    View/Open
    pvt_143_05_051503.pdf (4.545Mb)
    Date
    2021
    Author
    Nagai, Masaki
    Lin, Shan
    Nakahata, Kazuyuki
    Metadata
    Show full item record
    Abstract
    Several components of nuclear power plants are made of cast austenitic stainless steel (CASS) because of its high corrosion resistance and strength. The inservice inspection based on ultrasonic testing (UT) has to be conducted for CASS components in accordance with fitness-for-service codes such as the Japan Society of Mechanical Engineers Rules on Fitness-for-Service for Nuclear Power Plants. However, a high-accuracy evaluation of flaws in CASS components through UT is difficult because the ultrasonic waves are scattered and attenuated by coarse grains, and their beam is distorted by the anisotropy resulting from the grain orientations. Numerical simulations are useful and reasonable ways for better understanding the ultrasonic wave propagation behavior in CASS. To effectively achieve this, the simulation model should include a three-dimensional (3D) grain structure. If a casting simulation can predict the solidification structure in a CASS, the wave propagation could be simulated also for a more realistic situation. In this study, we predicted the solidification structure of statically CASS by using a cellular automaton (CA) coupled with the finite element method and fed this structure into an explicit finite element model (FEM) for simulating the propagation of waves emitted by angle beam probes. Afterward, these simulated wave propagations were compared with those measured by a 3D laser Doppler vibrometer (LDV), showing almost good agreement between predicted and experimental results.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276699
    Collections
    • Journal of Pressure Vessel Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV