Forced Vibration Tests for In-Line Vortex-Induced Vibration to Assess Partially Strake-Covered Pipeline Spans
View/ Open
Date
2020Author
Wu, Jie
Yin, Decao
Passano, Elizabeth
Lie, Halvor
Peek, Ralf
Sequeiros, Octavio E.
Ang, Sze Yu
Bernardo, Chiara
Atienza, Meliza
Metadata
Show full item recordAbstract
Helical strakes can suppress vortex-induced vibrations (VIVs) in pipelines spans and risers. Pure in-line (IL) VIV is more of a concern for pipelines than for risers. To make it possible to assess the effectiveness of partial strake coverage for this case, an important gap in the hydrodynamic data for strakes is filled by the reported IL forced-vibration tests. Therein, a strake-covered rigid cylinder undergoes harmonic purely IL motion while subject to a uniform “flow” created by towing the test rig along SINTEF Ocean's towing tank. These tests cover a range of frequencies, and amplitudes of the harmonic motion to generate added-mass and excitation functions are derived from the in-phase and 90 deg out-of-phase components of the hydrodynamic force on the pipe, respectively. Using these excitation- and added-mass functions in VIVANA together with those from experiments on bare pipe by Aronsen (2007 “An Experimental Investigation of In-Line and Combined In-Line and Cross-Flow Vortex Induced Vibrations,” Ph.D. thesis, Norwegian University of Science and Technology, Trondheim, Norway.), the IL VIV response of partially strake-covered pipeline spans is calculated. It is found that as little as 10% strake coverage at the optimal location effectively suppresses pure IL VIV.