• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Simplified Algorithm for Count Rate Processing in Radiation Monitors That Address Statistical Fluctuations and Spurious Counts

    Thumbnail
    View/Open
    ners_007_04_042001.pdf (637.6Kb)
    Date
    2021
    Author
    Nanda, Biswamohan
    Madhavi, Voleti
    Suguna Devi, S. V.
    Balachandran, R.
    Metadata
    Show full item record
    Abstract
    While processing the signals from radiation detectors, for finding the true mean-count-rate, algorithms with hybrid pulse collection methodology have been proposed and used over the years. An algorithm based on this technique with a new methodology of adoption and implementation including spurious rejection is proposed here. It enables a specified and controllable error when the mean-count-rate remains within certain predefined limits from its true value. Effort is made to optimize the response time of prediction at low count rates preserving the optimum possible relative-standard-deviation (RSD). Chi-squared test is utilized for verifying the counting system to check if the observed fluctuations are consistent with the expected statistical fluctuations. A C-program code has been developed to test the algorithm. An observed set of detector outputs are given as input to the program and the corresponding Output is analyzed. A comparative study between the proposed method and floating-mean method is presented for the same set of observations. A typical short-lived high voltage (HV) induced spurious noise pattern is fed as input to the program verifying limited-spurious rejection capability of the algorithm. An embedded C program was written for microcontroller implementation of the algorithm. Case-study of a neutron roentgen equivalent man (REM) counter is presented for evaluating response time for various ranges of operation with calculation of RSD at these ranges. This general-purpose algorithm can enhance the read-out accuracy of radiation monitors used for radiation safety applications.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276559
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV