• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Noise Reduction of Ceiling Fans in Mass Production Applying DMAIC-Six Sigma Approach

    Thumbnail
    View/Open
    nde_4_3_031006.pdf (2.409Mb)
    Date
    2021
    Author
    Hasan, Md. Zahid
    Ahammed, Rubel
    Metadata
    Show full item record
    Abstract
    Success and business reputation depend upon the quality of products where product quality relies on the capability of a process, yield value, sigma score, etc. The poor quality of ceiling fans was determined from the Pareto analysis of the define, measure, analyze, improve and control (DMAIC) model, which was humming noise during running, and further actions were undertaken regarding the reduction of the humming noise. Noise data were collected from random samples to determine the current sigma score, which was 3.14. Also, the weak value (1.05) of the Process Potential Index implied that the process condition was below the standard (< 1.33) and needed to be improved badly. Then, root cause analysis and relationship diagram were used to identify the possible causes. With the design of experiments and correlation analysis, it was clear that the air gap between the stator and rotor was the main culprit behind the humming noise. The suitable range of air gap was determined from boxplot analysis, which was 0.2 mm–0.225 mm and the corresponding amount of sound level in dB (37.5–40.3 dB) for a 0.225-mm air gap with the watt consumption (83 w) from the hypothesis test for the corresponding air gap. Finally, the updated sigma score and process capability analysis were performed with control charts to show the comparison after applying the DMAIC-Six Sigma methodology. The final sigma score was 5.1, which indicates a significant improvement of the process with the capability of saving 23,438 USD/year caused by the poor quality of ceiling fans.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276457
    Collections
    • Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV