Show simple item record

dc.contributor.authorWhalen, Mallory
dc.contributor.authorChang-Davidson, Elizabeth
dc.contributor.authorMoran, Terra
dc.contributor.authorHoffman, Rachel
dc.contributor.authorFrydman, Galit H.
dc.contributor.authorSlocum, Alexander
dc.contributor.authorDangel, Alissa
dc.date.accessioned2022-02-05T21:49:46Z
dc.date.available2022-02-05T21:49:46Z
dc.date.copyright12/18/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn1932-6181
dc.identifier.othermed_015_02_021002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276422
dc.description.abstractVaginal delivery is typically avoided in the extremely preterm breech population due to the concern of entrapment by the cervix of the aftercoming head. A mechanical device concept is presented to enable vaginal delivery by preventing retraction of the cervix against the fetus during delivery. The two-part device was designed to dilate the cervix, prevent prolapse of small fetal parts and maintain sufficient dilation during delivery. The two-part device was designed and manufactured with the following modules: an inflatable saline-filled cervical balloon for dilation and a cervical retractor composed of semirigid beams to stabilize the cervix and maintain adequate dilation. The device was tested using a cervical phantom designed to simulate the compressive force the cervix exerts. The cervical balloon reached a maximum dilation of 8.5 cm, after which there was leakage of saline from the balloon. While this dilation was less than the target goal of 10 cm, the leaking was attributed to prototype manufacturing defects, which could be resolved with further development. The cervical retractor was able to withstand between 1–3 kPa. Although estimates of cervical pressure values can be upward of 30 kPa, there are no in vivo measurements to formally identify the pressure values for patients in preterm labor. This device serves as a viable proof-of-concept for utilizing an inflatable balloon device to prevent cervical retraction in the setting of extremely preterm vaginal breech delivery. Further manufacturing improvements and design changes could improve the device for continued development and testing.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDevice Prototype for Vaginal Delivery of Extremely Preterm Fetuses in the Breech Presentation
dc.typeJournal Paper
dc.journal.volume15
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4049086
dc.journal.fristpage021002-1
dc.journal.lastpage021002-7
dc.page7
dc.treeJournal of Medical Devices:;2020:;volume( 015 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record