    Characterization of Acetabular Cup Insertion Forces in Cancellous Bone Proxy for Validation of an Invasive Sensing Model and Development of Automatic Prosthesis Installation Device: A Preliminary Study

    Thumbnail
    View/Open
    med_015_02_021001.pdf (2.465Mb)
    Date
    2020
    Author
    Behzadi, Kambiz
    Rusk, Jesse
    Metadata
    Show full item record
    Abstract
    Total hip replacement is a widespread medical procedure, with over 300,000 surgeries performed each year in the United States alone. The vast majority of total hip replacements utilize press fit fixation. Successful seating of the implant requires a delicate balance between inserting the implant deep enough to obtain sufficient primary stability, while avoiding fracture of bone. To improve patient outcomes, surgeons need assistive technologies that can guide them as to how much force to apply and when to stop impacting. The development of such technology, however, requires a greater understanding of the forces experienced in bone and the resulting cup insertion and implant stability. Here, we present a preliminary study of acetabular cup insertion into bone proxy samples. We find that as the magnitude of force on the acetabular cup increases, cup insertion and axial extraction force increase linearly, then nonlinearly, and finally plateau with full insertion. Within the small nonlinear zone, approximately 90% of both cup insertion and extraction force are achieved with only 50% total energy required for full seating, posing the question as to whether full seating is an appropriate goal in press-fit arthroplasty. For repeated impacts of a given energy, cup displacement and force experienced in bone (measured force profile—MFP) increase correspondingly and reach a plateau over a certain number of impacts (number of impacts to seating—NOITS), which represents the rate of insertion. The relationship between MFP and NOITS can be exploited to develop a force feedback mechanism to quantitatively infer optimal primary implant stability.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276421
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV