• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Application-Specific Learning Curve With a Modern Computer-Assisted Orthopedic Surgery System for Joint Arthroplasty

    Thumbnail
    View/Open
    med_015_01_014504.pdf (845.3Kb)
    Date
    2021
    Author
    Dai, Yifei
    Kusuma, Sharat
    Greene, Alexander T.
    Fan, Wen
    Jung, Amaury
    Hamad, Cyril
    Bras, Guillaume
    Angibaud, Laurent
    Metadata
    Show full item record
    Abstract
    A commonly acknowledged barrier for the adoption of new computer-assisted orthopedic surgery (CAOS) technologies relates to a perceived long and steep learning curve. However, this perception has not been objectively tested with the consideration of surgeon-specific learning approaches. This study employed the cumulative sum control chart (CUSUM) to investigate individual surgeon's learning of CAOS technology by monitoring the stability of the surgical process regarding surgical time. Two applications for total knee arthroplasty (TKA) and two applications for total shoulder arthroplasty (TSA) provided by a modern CAOS system were assessed with a total of 21 surgeons with different levels of previous CAOS experience. The surgeon-specific learning durations identified by CUSUM method revealed that CAOS applications with “full guidance” (i.e., those that offer comprehensive guidance, full customization, and utilize CAOS-specific instrumentation) required on average less than ten cases to learn, while the streamlined application designed as a CAOS augmentation of existing mechanical instrumentation demonstrated a minimal learning curve (less than three cases). During the learning phase, the increase in surgical time was found to be moderate (approximately 15 min or less) for the “full guidance” applications, while the streamlined CAOS application only saw a clinically negligible time increase (under 5 min). The CUSUM method provided an objective and consistent measurement on learning, and demonstrated, contrary to common perception, a minimal to modest learning curve required by the modern CAOS system studied.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276418
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV