dc.contributor.authorBüchler, Philippe
dc.contributor.authorRäber, Jonas
dc.contributor.authorVoumard, Benjamin
dc.contributor.authorBerger, Steve
dc.contributor.authorBell, Brett
dc.contributor.authorSutter, Nino
dc.contributor.authorFunariu, Stefan
dc.contributor.authorHasler, Carol
dc.contributor.authorStuder, Daniel
dc.date.accessioned2022-02-05T21:49:32Z
dc.date.available2022-02-05T21:49:32Z
dc.date.copyright2/9/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn1932-6181
dc.identifier.othermed_015_01_011111.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276414
dc.description.abstractDegenerative spine problems and spinal deformities have high socio-economic impacts. Current surgical treatment is based on bony fusion that can reduce mobility and function. Precise descriptions of the biomechanics of normal, deformed, and degenerated spinal segments under in vivo conditions are needed to develop new approaches that preserve spine function. This study developed a system that intraoperatively measures the three-dimensional segmental stiffness of patient's spine. SpineBot, a parallel kinematic robot, was developed to transmit loads to adjacent vertebrae. A force/torque load cell mounted on the SpineBot measured the moment applied to the spinal segment and calculated segmental stiffnesses. The accuracy of SpineBot was characterized ex vivo by comparing its stiffness measurement of five ovine specimens to measurements obtained with a reference spinal testing system. The SpineBot can apply torques up to 10 N·m along all anatomical axes with a total range of motion of about 11.5 deg ± 0.5 deg in lateral bending, 4.5 deg ± 0.3 deg in flexion/extension, and 2.6 deg ± 0.5 deg in axial rotation. SpineBot's measurements are noisier than the reference system, but the correlation between SpineBot and reference measurements was high (R2 > 0.8). In conclusion, SpineBot's accuracy is comparable to that of current reference systems but can take intraoperative measurements. SpineBot can improve our understanding of spinal biomechanics in patients who have the pathology of interest, and take these measurements in the natural physiological environment, giving us information essential to developing new “nonfusion” products.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Spinebot—A Robotic Device to Intraoperatively Quantify Spinal Stiffness
dc.typeJournal Paper
dc.journal.volume15
dc.journal.issue1
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4049915
dc.journal.fristpage011111-1
dc.journal.lastpage011111-7
dc.page7
dc.treeJournal of Medical Devices:;2021:;volume( 015 ):;issue: 001
dc.contenttypeFulltext