Show simple item record

dc.contributor.authorMurali, Barathwaj
dc.contributor.authorBelvroy, Viony M.
dc.contributor.authorPandey, Shivam
dc.contributor.authorBismuth, Jean
dc.contributor.authorByrne, Michael D.
dc.contributor.authorO'Malley, Marcia K.
dc.date.accessioned2022-02-05T21:49:25Z
dc.date.available2022-02-05T21:49:25Z
dc.date.copyright1/28/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn1932-6181
dc.identifier.othermed_015_01_011107.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276411
dc.description.abstractEndovascular navigation proficiency requires a significant amount of manual dexterity from surgeons. Objective performance measures derived from endovascular tool tip kinematics have been shown to correlate with expertise; however, such metrics have not yet been used during training as a basis for real-time performance feedback. This paper evaluates a set of velocity-based performance measures derived from guidewire motion to determine their suitability for online performance evaluation and feedback. We evaluated the endovascular navigation skill of 75 participants using three metrics (spectral arc length, average velocity, and idle time) as they steered tools to anatomical targets using a virtual reality simulator. First, we examined the effect of navigation task and experience level on performance and found that novice performance was significantly different from intermediate and expert performance. Then we computed correlations between measures calculated online and spectral arc length, our “gold standard” metric, calculated offline (at the end of the trial, using data from the entire trial). Our results suggest that average velocity and idle time calculated online are strongly and consistently correlated with spectral arc length computed offline, which was not the case when comparing spectral arc length computed online and offline. Average velocity and idle time, both time-domain based performance measures, are therefore more suitable measures than spectral arc length, a frequency-domain based metric, to use as the basis of online performance feedback. Future work is needed to determine how to best provide real-time performance feedback to endovascular surgery trainees based on these metrics.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleVelocity-Domain Motion Quality Measures for Surgical Performance Evaluation and Feedback
dc.typeJournal Paper
dc.journal.volume15
dc.journal.issue1
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4049310
dc.journal.fristpage011107-1
dc.journal.lastpage011107-11
dc.page11
dc.treeJournal of Medical Devices:;2021:;volume( 015 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record