Show simple item record

dc.contributor.authorJain, Aseem
dc.contributor.authorScavo, Laura
dc.contributor.authorCross, Damian
dc.contributor.authorMarra, Steven P.
dc.contributor.authorNimgaonkar, Ashish
dc.date.accessioned2022-02-05T21:49:04Z
dc.date.available2022-02-05T21:49:04Z
dc.date.copyright10/16/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn1932-6181
dc.identifier.othermed_014_04_041007.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276398
dc.description.abstractCirrhosis of the liver is often accompanied by refractory ascites, a condition characterized by fluid buildup in the peritoneal cavity that does not respond to diuretics or recurs shortly after therapeutic paracentesis. There are several management strategies in practice including large-volume paracentesis, transjugular intrahepatic portosystemic shunts, peritoneovenous shunting, and liver transplant. However, each of these options come with limitations such as high cost, poor efficacy, and increased risk of complications. This article explores a new management strategy with a novel biopowered shunt, the PeriLeve device, that moves fluid from the peritoneal cavity to the urinary bladder using natural changes in intra-abdominal pressure (IAP). By doing so, PeriLeve shifts the current paradigm of care from the hospital to the home which reduces costs to healthcare providers and patients while improving quality of life. The basic design of the pump consists of two check (i.e., one-way) valves on either side of a fluid filled cavity which is separated from an air cavity by an elastomeric membrane. This article presents benchtop testing results of a prototype PeriLeve pump. The performance of the pump was analyzed along six parameters: change in intra-abdominal pressure, valve opening pressure, membrane thickness, membrane stiffness, membrane surface area, and air cavity volume. Initial results indicate that, with future optimizations, the pump can ultimately move a clinically significant volume of fluid.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExploring a New Management Option for Patients With Refractory Ascites: The PeriLeve Device
dc.typeJournal Paper
dc.journal.volume14
dc.journal.issue4
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4048616
dc.journal.fristpage041007-1
dc.journal.lastpage041007-6
dc.page6
dc.treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record