Show simple item record

dc.contributor.authorSera, Toshihiro
dc.contributor.authorKamiya, Naoki
dc.contributor.authorFukushima, Taichi
dc.contributor.authorTanaka, Gaku
dc.date.accessioned2022-02-05T21:46:06Z
dc.date.available2022-02-05T21:46:06Z
dc.date.copyright3/24/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn0148-0731
dc.identifier.otherbio_143_07_074501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276301
dc.description.abstractWe visualized the flow patterns in an alveolated duct model with breathing-like expanding and contracting wall motions using particle image velocimetry, and then, we investigated the effect of acinar deformation on the flow patterns. We reconstructed a compliant, scaled-up model of an alveolated duct from synchrotron microcomputed tomography images of a mammalian lung. The alveolated duct did not include any bifurcation, and its entire surface was covered with alveoli. We embedded the alveolated duct in a sealed container that was filled with fluid. We oscillated the fluid in the duct and container simultaneously and independently to control the flow and duct volume. We examined the flow patterns in alveoli, with the Reynolds number (Re) at 0.03 or 0.22 and the acinar volume change at 0%, 20%, or 80%. At the same Re, the heterogeneous deformation induced different inspiration and expiration flow patterns, and the recirculating regions in alveoli changed during respiratory cycle. During a larger acinar deformation at Re = 0.03, the flow patterns tended to change from recirculating flow to radial flow during inspiration and vice versa during expiration. Additionally, the alveolar geometric characteristics, particularly the angle between the alveolar duct and mouth, affected these differences in flow patterns. At Re = 0.22, recirculating flow patterns tended to form during inspiration and expiration, regardless of the magnitude of the acinar deformation. Our in vitro experiments suggest that the alveolated flows with nonself-similar and heterogeneous wall motions may promote particle mixing and deposition.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleVisualizing the Flow Patterns in an Expanding and Contracting Pulmonary Alveolated Duct Based on Microcomputed Tomography Images
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue7
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4050285
dc.journal.fristpage074501-1
dc.journal.lastpage074501-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record