    An Efficient Assisted Bidirectional Glenn Design With Lowered Superior Vena Cava Pressure for Stage-One Single Ventricle Patients

    Thumbnail
    View/Open
    bio_143_07_071008.pdf (3.623Mb)
    Date
    2021
    Author
    Jia, Dongjie
    Peroni, Matthew
    Khalapyan, Tigran
    Esmaily, Mahdi
    Metadata
    Show full item record
    Abstract
    Recently, the assisted bidirectional Glenn (ABG) procedure has been proposed as an alternative to the modified Blalock–Taussig shunt (mBTS) operation for neonates with single-ventricle physiology. Despite success in reducing heart workload and maintaining sufficient pulmonary flow, the ABG also raised the superior vena cava (SVC) pressure to a level that may not be tolerated by infants. To lower the SVC pressure, we propose a modified version of the ABG (mABG), in which a shunt with a slit-shaped nozzle exit is inserted at the junction of the right and left brachiocephalic veins. The proposed operation is compared against the ABG, the mBTS, and the bidirectional Glenn (BDG) operations using closed-loop multiscale simulations. Both normal (2.3 Wood units-m2) and high (7 Wood units-m2) pulmonary vascular resistance (PVR) values are simulated. The mABG provides the highest oxygen saturation, oxygen delivery, and pulmonary flow rate in comparison to the BDG and the ABG. At normal PVR, the SVC pressure is significantly reduced below that of the ABG and the BDG (mABG: 4; ABG: 8; BDG: 6; mBTS: 3 mmHg). However, the SVC pressure remains high at high PVR (mABG: 15; ABG: 16; BDG: 12; mBTS: 3 mmHg), motivating an optimization study to improve the ABG hemodynamics efficiency for a broader range of conditions in the future. Overall, the mABG preserves all advantages of the original ABG procedure while reducing the SVC pressure at normal PVR.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276290
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV