Show simple item record

dc.contributor.authorLi, Wuyang
dc.contributor.authorTrbojevic, Sara
dc.contributor.authorAlmarza, Alejandro J.
dc.date.accessioned2022-02-05T21:43:02Z
dc.date.available2022-02-05T21:43:02Z
dc.date.copyright3/12/2021 12:00:00 AM
dc.date.issued2021
dc.identifier.issn0148-0731
dc.identifier.otherbio_143_06_064501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276201
dc.description.abstractThis technical brief explores the validity and trueness of fit for using the transverse isotropic biphasic and Kelvin models (first and second order generalized) for characterization of the viscoelastic tensile properties of the temporomandibular joint (TMJ) discs from pigs and goats at a strain rate of 10 mm/min. We performed incremental stress-relaxation tests from 0 to 12% strain, in 4% strain steps on pig TMJ disc samples. In addition, to compare the outcomes of these models between species, we also performed a single-step stress-relaxation test of 10% strain. The transverse isotropic biphasic model yielded reliable fits in reference to the least root mean squared error method only at low strain, while the Kelvin models yielded good fits at both low and high strain, with the second order generalized Kelvin model yielding the best fit. When comparing pig to goat TMJ disc in 10% strain stress-relaxation test, unlike the other two Kelvin models, the transverse isotropic model did not fit well for this larger step. In conclusion, the second order Kelvin model showed the best fits to the experimental data of both species. The transverse isotropic biphasic model did not fit well with the experimental data, although better at low strain, suggesting that the assumption of water flow only applies while uncrimping the collagen fibers. Thus, it is likely that the permeability from the biphasic model is not truly representative, and other biphasic models, such as the poroviscoelastic model, would likely yield more meaningful outputs and should be explored in future works.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleComparison of the Trueness of Fits of the Biphasic Transverse Isotropic and Kelvin Models to the Tensile Behavior of Temporomandibular Joint Disc
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue6
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4050033
dc.journal.fristpage064501-1
dc.journal.lastpage064501-7
dc.page7
dc.treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record