• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Mechanisms and Robotics
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Mechanisms and Robotics
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Characterization, Design, and Experimentation of a Fabric-Based Wearable Joint Sensing Device on Human Elbow

    Thumbnail
    View/Open
    jmr_13_3_031110.pdf (1.640Mb)
    Date
    2021
    Author
    Lau, Jun Liang
    Soh, Gim Song
    Metadata
    Show full item record
    Abstract
    The use of conductive fabrics (CFs) in the design of wearables for joint sensing has recently received much interest in a wide range of applications such as robotics, rehabilitation, personal wellness, and sports. However, one key limitation in the existing measurement approach is that the user’s anthropometric information is required to relate the joint parameters to the CF sensor strain reading. This paper seeks to address this limitation by evaluating a new wearable device concept that comprises a CF strain–voltage sensor embedded as part of an inverted slider-crank (ISC) mechanism for joint extension sensing. This benefits from not requiring anthropometric information from the user to relate the joint parameters to the fabric strain readings, as opposed to an existing design. We first characterize the electromechanical property of a commercially available CF. Second, we formulate the joint sensing device’s geometric synthesis procedure as a constrained revolute joint system, where the CF is designed and introduced as an RPR chain to obtain an ISC linkage. Lastly, we designed our wearable sensing device and validated against an ISC linkage fixture representing an elbow joint and an actual healthy human subject’s left elbow. The ISC linkage fixture experimental setup shows that our designed joint sensing device can track the elbow extension motion of 140 deg with a maximum error of 7.66%. The results from our human subject’s left elbow show that it can track the elbow flexion–extension at various angular motion, with error ranges between 8.24 deg and 12.86 deg, and have provided us with an acceptable average Spearman’s coefficient values rs at 0.95.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276088
    Collections
    • Journal of Mechanisms and Robotics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV