    A Dual-VENC Four-Dimensional Flow MRI Framework for Analysis of Subject-Specific Heterogeneous Nonlinear Vessel Deformation

    Thumbnail
    View/Open
    bio_142_11_114502.pdf (3.621Mb)
    Date
    2020
    Author
    Concannon, J.
    Hynes, N.
    McMullen, M.
    Smyth, E.
    Moerman, K.
    McHugh, P. E.
    Sultan, S.
    Karmonik, C.
    McGarry, J. P.
    Metadata
    Show full item record
    Abstract
    Advancement of subject-specific in silico medicine requires new imaging protocols tailored to specific anatomical features, paired with new constitutive model development based on structure/function relationships. In this study, we develop a new dual-velocity encoding coefficient (VENC) 4D flow MRI protocol that provides unprecedented spatial and temporal resolution of in vivo aortic deformation. All previous dual-VENC 4D flow MRI studies in the literature focus on an isolated segment of the aorta, which fail to capture the full spectrum of aortic heterogeneity that exists along the vessel length. The imaging protocol developed provides high sensitivity to all blood flow velocities throughout the entire cardiac cycle, overcoming the challenge of accurately measuring the highly unsteady nonuniform flow field in the aorta. Cross-sectional area change, volumetric flow rate, and compliance are observed to decrease with distance from the heart, while pulse wave velocity (PWV) is observed to increase. A nonlinear aortic lumen pressure–area relationship is observed throughout the aorta such that a high vessel compliance occurs during diastole, and a low vessel compliance occurs during systole. This suggests that a single value of compliance may not accurately represent vessel behavior during a cardiac cycle in vivo. This high-resolution MRI data provide key information on the spatial variation in nonlinear aortic compliance, which can significantly advance the state-of-the-art of in-silico diagnostic techniques for the human aorta.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4275973
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV