Show simple item record

dc.contributor.authorChilds, Mason
dc.contributor.authorMuyshondt, Robert
dc.contributor.authorVaghetto, Rodolfo
dc.contributor.authorNguyen, Duy Thien
dc.contributor.authorHassan, Yassin
dc.date.accessioned2022-02-04T22:18:43Z
dc.date.available2022-02-04T22:18:43Z
dc.date.copyright9/4/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn0098-2202
dc.identifier.otherpvt_143_02_021401.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275316
dc.description.abstractThe thermal-hydraulic behavior of the flow in rod bundles has motivated numerous experimental and computational investigations. Previous studies have identified potential for accumulation of debris within the small subchannels of typical wire-wrapped assemblies with subsequent total or partial blockage of subchannel coolant flow. A test campaign was conducted to study the effects of localized blockages on the bundle averaged friction factor of a tightly packed wire-wrapped rod bundle. Blockages were installed within the bundle, and fluid pressure drop was measured across one wire pitch for a Reynolds number range of 500–17,200. The Darcy–Weisbach friction factor of the perturbed rod bundle geometry was compared with that of the unblocked bundle, as well as with the predictions of a well-established friction factor correlation. Differing effects based on blockage size and location for various flow regimes were studied. A number of conclusions can be made about the effects of the blockages on the friction factor, such as an increasing effect of the blockage on friction factor with an increase in Reynolds number, a change in flow behavior in the turbulent transition flow regime near Reynolds number 3000, differences in effect on friction factor for different types of subchannel blockage, and a nonlinear trend in friction factor variation with flow area impeded for edge subchannels. To this end, all data and quantified uncertainty produced in this study are made available for comparison and validation of advanced computational tools.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental Study on the Effect of Localized Blockages on the Friction Factor of a 61-Pin Wire-Wrapped Bundle
dc.typeJournal Paper
dc.journal.volume142
dc.journal.issue11
dc.journal.titleJournal of Fluids Engineering
dc.identifier.doi10.1115/1.4048140
dc.journal.fristpage0111211-1
dc.journal.lastpage0111211-8
dc.page8
dc.treeJournal of Fluids Engineering:;2020:;volume( 142 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record