dc.description.abstractThis literature review was conducted to evaluate liver biopsy adequacy, including total core length (TCL), number of portal tracts (PT), fragmentation, and complication rates, as a function of needle type and gauge. A systematic electronic search was performed in the Web of Science and Google Scholar databases, according to the PRISMA statement. Eligible data, describing in vivo percutaneous ultrasound-guided human liver biopsy quality outcomes, were compared to adequacy criteria of the American Association for the Study of Liver Diseases (AASLD, TCL ≥ 20 mm, PT ≥ 11). An adequate mean number of PTs was found in 83% of biopsy needles assessed between 2012 and 2019, compared to 0% between 1998 and 2004. For TCL, this was 44% and 33%, respectively. Increasing the needle diameter enhanced TCL (result in 50% of included studies) and PT count (100%), and reduced fragmentation rates (75%), whereas no effect on pain or complications was found (83%). In total, five needle types achieved adequate PT counts, using 16 G (3×), 17 G (1×), or 18 G (1×) needles. Adequacy was reached using either a core needle biopsy (CNB, 3×) approach with one pass, or a fine needle aspiration (FNA, 2×) approach with two passes. The recommendations for biopsy adequacy can be met using 16/17 G FNA or 16/18 G CNB needles. Currently, many publications still present substandard liver biopsy quality outcomes. Although minimizing biopsy invasiveness is desirable, a decreased diameter or number of passes is ill-judged when reliability of biopsy outcomes is at stake.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleUltrasound-Guided Percutaneous Liver Biopsy: A Review on Obtaining Adequate Specimens
dc.typeJournal Paper
dc.journal.volume14
dc.journal.issue3
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4047543
dc.journal.fristpage034503-1
dc.journal.lastpage034503-14
dc.page14
dc.treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 003